1 × ৳ 4,800.00
-
1 × ৳ 5,200.00
-
1 × ৳ 15,500.00
-
1 × ৳ 18,600.00
-
1 × ৳ 9,200.00
-
1 × ৳ 1,280.00
-
2 × ৳ 1,100.00
-
1 × ৳ 4,600.00
-
1 × ৳ 1,320.00
-
1 × ৳ 920.00
-
1 × ৳ 5,220.00
-
1 × ৳ 11,960.00
-
1 × ৳ 1,310.00
-
1 × ৳ 880.00
-
1 × ৳ 800.00
-
1 × ৳ 1,100.00
-
1 × ৳ 5,200.00
-
1 × ৳ 194,000.00
-
1 × ৳ 1,280.00
-
1 × ৳ 1,280.00
-
1 × ৳ 4,380.00
-
1 × ৳ 9,400.00
-
1 × ৳ 16,490.00
-
1 × ৳ 390,000.00
-
2 × ৳ 4,800.00
-
1 × ৳ 3,660.00
-
1 × ৳ 5,860.00
-
1 × ৳ 3,300.00
-
1 × ৳ 175,000.00
-
1 × ৳ 27,000.00
-
1 × ৳ 52,000.00
-
1 × ৳ 5,900.00
-
1 × ৳ 980.00
-
1 × ৳ 15,000.00
-
1 × ৳ 620.00
-
1 × ৳ 990.00
-
1 × ৳ 680.00
-
1 × ৳ 3,920.00
-
1 × ৳ 23,800.00
-
1 × ৳ 2,372.00
-
1 × ৳ 2,225.00
-
1 × ৳ 8,800.00
-
1 × ৳ 1,280.00
-
1 × ৳ 2,750.00
-
1 × ৳ 1,380.00
-
1 × ৳ 39,500.00
-
1 × ৳ 65,000.00
-
1 × ৳ 500.00
-
1 × ৳ 9,440.00
-
1 × ৳ 4,750.00
-
1 × ৳ 4,600.00
-
1 × ৳ 620,000.00
Roll over image to zoom in
Coagulation Analyzer, D-CG44 (Four-channels)
৳ 240,000.00
Coagulation Analyzer, D-CG44 (Four-channels)
- A friendly operating system, large LCD display
- Advanced optical lighting principle and percentage analysis ensure accurate results
- Special cup location testing system, the addition of sample bracket
- Optional PT Fibrinogen testing method, deletion of reagent dosage
- Open reagent system, low reagent consumption up to 20ul
Features:
- A friendly operating system, large LCD display
- Advanced optical lighting principle and percentage analysis ensure accurate results
- Special cup location testing system, the addition of sample bracket
- Optional PT Fibrinogen testing method, deletion of reagent dosage
- Open reagent system, low reagent consumption up to 20ul
- Top quality thermostat, 37±0.3°C accuracy
- Precise dispensing: CV < 3%
- 10,000 test results memory.
- Internal thermal-sensitive printer
- Electronically linked pipette
- Conduct all routine tests such as PT, APTT, TT, fibrinogen and coagulation factors
- Data management PC connection (RS-232 interface)
Testing channel: | 4 channels |
Analysis mode: | 4 different parameters analysis in the same time |
Sample incubation positions: | 24 |
Reagent incubation positions: | 6 |
Software timer: | 4 |
Test wavelength: | 470nm |
Sample volume: | 20uL-40ul |
Reagent volume: | 20uL-40ul |
Temp control precision: | 37±0.3℃ |
Memory: | 10,000 test results |
Notation of Result: | S, %, PTR, INR, g/L |
Analysis mode: | LCD (240*128) |
Output: | Built-in thermal printer |
Input: | Keypad |
Interface: | RS-232 |
Power supply: | AC220V±15%, 50-60Hz |
Working Condition: | Temperature 15℃-30℃, Humidity ≤90% |
Dimension: | 395*320*135mm (L*W*H) |
Net Weight: | 7Kg |